DESIGNING OVERVOLTAGE AND UNDERVOLTAGE TRIPPING CIRCUIT FOR DISTRIBUTED SYSTEM LOAD WITH GSM ALERT USING MICROCONTROLLER
Main Article Content
Abstract
The main aims of this project to alert the relay when some difference in supply power for shield electrical home equipment and industrial instrument under over-voltage and under-voltage. The chances of damaged electronic devices are more because the equipment is much conscious in different power supply. In this scenario, it needs an extra shield system to shield the instrument by a different power. With the voltage comparator integrated circuits decide the trip of relay system get function as the voltage differs higher than or down the set worth. The major profit by that it also shields the 3-phase device from 1-phase and variation of power in ac power waveform. In the coming days it also possible earth fault detection and protection.
Downloads
Metrics
Article Details
This work is licensed under a Creative Commons Attribution 4.0 International License.
Licensing
TURCOMAT publishes articles under the Creative Commons Attribution 4.0 International License (CC BY 4.0). This licensing allows for any use of the work, provided the original author(s) and source are credited, thereby facilitating the free exchange and use of research for the advancement of knowledge.
Detailed Licensing Terms
Attribution (BY): Users must give appropriate credit, provide a link to the license, and indicate if changes were made. Users may do so in any reasonable manner, but not in any way that suggests the licensor endorses them or their use.
No Additional Restrictions: Users may not apply legal terms or technological measures that legally restrict others from doing anything the license permits.
References
. J.B GUPTA (2018) A COURSE IN POWER SYSTEMS, PART-III: Switchgear and Protection, Chapter-9.
] ROBERT L. BOYLESTAD, LOUIS NASHELSKY (2015) Electronic Devices and Circuit Theory 11th Edition,
Chapter-10.
. “IEEE Recommended Practice for Monitoring Electric Power Quality,” IEEE Std. 1159-1995, June 1995.
. Girish Chandra Thakur, Kumar Shantanu Kaushal, Manish Ranjan, Sandip kumar Gupta. “Implementation of single
phasing, over voltage, under voltage, Protection of Three Phase Appliances without using Microcontroller” , Int. journal
of Engineering Research and Applications,ISSN:2248-9622, vol. 5, Issue 5, (Part-6), pp.110-115,May 2015.
. Sourav Ghosh, Soumik Bakshi, saurav Ghosh, Rahul kundu, Indrajit Koleys. “Development of a low cost under
voltage and over current protection device”, Int. Journal of Advance Research in Electrical, Electronics and
Instrumentation Engineering, ISSN: 2278-8875, vol.5, Issue 5, May 2016.
. Gorkshanath Bhosale, Aakash Vakhare, Abhishek Kaystha, Amol Aher, Vishal Pansare. “Overvoltage,
Undervoltage, Protection of Electrical Equipment”, Int. Research Journal of Engineering and Technology(IRJET),